How to Replace the RBC17 Battery for APC UPS Models BE650G1, BE750G, BR700G, BE850M2, BE850G2, BX850M, BE650G, BN600, BN700MC, and BN900M

High-quality replacement batteries like the RBC17 are made to work with specific APC Uninterruptible Power Supply (UPS) models, such as BE650G1, BE750G, BR700G, BE850M2, BE850G2, BX850M, BN600, BN700MC, and BN900M. During blackouts, this sealed lead-acid battery helps customers keep their vital gadgets powered on and gives them peace of mind in times of need.
Because the RBC17 is a user-replaceable battery, installation is simple even without expert help. Because of its hot-swappable architecture, replacing it doesn’t need turning off any connected devices. The battery has a three to five year lifespan, depending on usage and climatic conditions, and is rated to meet or beyond OEM criteria, offering consistent performance for home and office UPS systems.
The RBC17 is a dependable choice for those wishing to prolong the life of their APC UPS and guarantee dependable power supply during unplanned outages. It is perfect for settings that demand constant backup.
Battery Quantity for Each UPS Model
Here’s a quick reference table showing the required number of RBC17 batteries for each compatible APC UPS model:
APC UPS Model | Required Battery (RBC17) |
BE650G1 | 1 |
BE750G | 1 |
BR700G | 1 |
BE850M2 | 1 |
BE850G2 | 1 |
BX850M | 1 |
BN600 | 1 |
BN700MC | 1 |
BN900M | 1 |
Each model requires one RBC17 battery for optimal performance. Regular battery checks and timely replacements will ensure the UPS provides reliable power backup when needed.
These are the APC UPS Battery Replacement Instructions with RBC17.
- Turn Off the UPS and Unplug Devices: Power down your UPS unit and unplug any connected devices to ensure safety during the battery replacement process.
- Unplug the UPS from Power Source: Disconnect the UPS from the wall outlet to prevent any electric shock.
- Access the Battery Compartment: Locate the battery compartment, typically found on the front or bottom of the UPS unit. Open the cover by sliding or unfastening screws as per your model’s instructions.
- Disconnect the Old Battery: Carefully disconnect the battery connectors (usually red for positive and black for negative) from the old battery. Ensure you remember the positioning to connect the new battery correctly.
- Remove the Old Battery: Slide out or lift the old battery from the compartment. Be cautious, as the battery may be heavy.
- Insert the New Battery (RBC17): Place the new RBC17 battery into the compartment, aligning it as the old one was.
- Reconnect the Battery Cables: Attach the connectors to the new battery, matching the positive (red) and negative (black) terminals. Ensure they are firmly connected.
- Close the Battery Compartment: Secure the compartment cover back in place, making sure it is properly closed.
- Plug in the UPS and Test: Reconnect the UPS to the power source and turn it on. The UPS should recognize the new battery, and any warning lights should clear after a few seconds.
- Charge the New Battery: Allow the UPS to charge the new battery for at least 8 hours to ensure it’s fully prepared for power backup.
Where to Buy
The APC RBC17 Replacement Battery is available on Amazon.com, providing a reliable power solution for compatible UPS models such as BE650G1, BE750G, BR700G, BE850M2, and others. Explore Amazon’s product listings to find the right replacement battery and keep your UPS system ready to protect your devices during power outages.